Bed head unit
ACRYLIC
Model code BHU.ACR.A0001.01
ACRYLIC is a high-end bedside unit designed for VIP hospital rooms. The smooth surface and refined appearance of the acrylic material bring a sense of elegance and prestige to the space.
With its minimal design and flawless surface language, it elevates the aesthetic perception of VIP patient rooms to the highest level. It is a premium solution for projects seeking a modern, clean, and exclusive look. Its carefully selected material and refined design approach add value to the environment.
- Channels
- 1 channel
- Length
- 1350 mm
- Depth
- 160 mm
- Height
- 195 mm
- Weight
- 10 kg
Standard colours
- RAL 9003Signal white
- RAL 9010Pure white
- RAL 9013Pearl white
- RAL 7016Anthracite grey
Colours and patterns can be changed on request.
Key features
- Premium Acrylic Surface & Minimal Design
- Design Suitable for VIP Room Concept
- Customizable Color and Finish Options
- LED lighting options (Direct / Indirect)
Optional features
- Nurse call system integration
- Custom socket and outlet configurations
Application areas
- VIP patient rooms
- Private clinic areas
- Palliative care
- High-end healthcare projects
Technical specifications
ACRYLIC

General
| Protection class | I |
|---|---|
| IP rating | IP 20 |
| Mains voltage | 100 / 240V |
| Mains frequency | 50 / 60 Hz |
| Operating temperature | 5 °C / 40°C |
| Storage temperature | -5°C / 40°C |
| Relative humidity | 30 - 85 % |
Mechanical
| Material | Aluminium extrusion profile, acrylic surface |
|---|---|
| Weight | 10 kg |
| Load capacity | Max. 25 kg/m |
| Recommended mounting height | 1600 mm (to gas outlets) |
Dimensions (mm)
| Length | 1350 (default) |
|---|---|
| Depth | 160 |
| Height | 195 |
Optional equipment
| Electrical sockets | Mains socket, UPS socket, grounding terminal, data socket |
|---|---|
| Electrical equipment | Quantity and type set per project, to DIN / BS / NF or other standards. |
| Medical gas outlets | Oxygen, nitrous oxide, medical air, surgical air, vacuum, carbon dioxide, nitrogen + AGSS |
| Medical equipment | Quantity and type set per project, to DIN / BS / NF or other standards. |
Standards
| Quality standards | EN ISO 13485 - EN ISO 9001 |
|---|---|
| Regulatory standards | 93/42 EEC - 2007/42/EC - EN ISO 14971 - EN ISO 15223 - EN 1041+A1 |
| Electrical standards | EN 60601-1 - EN 60601-1-2 - IEC 62366 |
| Electrical tests | EMC - LVD |
| Medical gas standards | EN ISO 7396-1 - EN ISO 7396-2 - EN ISO 9170-1 |
Packaging
| Packaging | Stretch film and foam |
|---|
Technical features
| Body Length | 1500 mm (standard) — customizable upon request |
|---|---|
| Accessory Rail | Not applicable on the unit. Can be installed on the wall as an alternative configuration for accessory integration. |
| Electrical Socket Options | Mains Socket, UPS Outlet, Grounding Terminal, Data Socket |
| Medical Gas Sockets Options | Oxygen (O₂), Nitrous Oxide (N₂O), Medical Air, Surgical Air, Vacuum, Carbon Dioxide (CO₂), Nitrogen (N₂), AGSS |
Specifications may change without notice. Images are examples and may differ by model.